Power factor controllers N-6, N-12 and NC-12 Nokian N-6 and N-12 Optimized user interface for easy operation Backlighted alphanumeric multisymbol LCD-display and ergonomic push buttons enable:
Viewing of electrical information
Easy browsing in the menus
Multilingual usage
Alarm indications Performance
Intelligent stepping algorithm for optimum step utilization and fast response
All traditional stepping sequences also available Simplified installation and set-up
Quick and simple mounting and wiring
Insensitive to current transformer polarity and phase rotation polarity
A special menu allows controller self-configuration Monitoring and protection Alarms
Should a disturbance occur on the network or in the capacitor bank, alarms are indicated on the screen and alarm contact closure is initiated
The alarm message is maintained on the screen once the fault clears and until it is manually reset
Last five alarms are stored in alarm log Protection
If necessary, the capacitor steps are automatically disconnected to protect the equipment NC-12 For more advanced power factor controlling In addition to the functions of N-6/ N-12, the NC-12 provides the following additional
features:
Measurement of total current harmonic distortion
Graphical analysis of network harmonic currents and voltages
Possibility of a dual target cos
Possible to configurate steps permanently switched off or on
Step condition monitoring
Time stamped alarm log
On-line help menus A communicating model
Optional communication auxiliary ( RS485 Modbus)
FANS ANUGRAH ELECTRIC We are a company engaged in the General Contractor, Electrical, Panel Maker. Please send your request specifications http://alatlistrikmurah.net/ Please Send Your Specification Request READY STOCK....!!! EMAIL: fansanugrahelectric@gmail.com Mobile / Message / WhatsApp +62 813 842 3 999 3 Fans Anugrah Electric * other type will be available on special request This NEW product, , NO SECOND...! ! ! ................ SPECIAL PRICE ! ! ............... relay: 1. ALSTOM / AREVA 2. ARTECHE 3. Crompton 4. CIRCULOR 5. MICRO 6. MITSUBISHI 7. SIEMENS 8. SCHNEIDER 9. SEG 10.ABB 11. etc FUSE: 1. SIBA 2. ETI 3. EFEN 4. GAE 5. BUSSMANN 6. JEAN MUELLER 7. etc HOT / GROUNDING STICK: 1. RITS 2. AB CHENG / HUBBLE 3. NEW PATH 4. NIHON 5. JITAI 6. etc Insulating: 1. RAYCHEM 2. 3M 3. Denson 4. Elastimold 5. COOPER 6. etc ARESSTER / CT / VT / PT / Panel Cubicle / Panel ATS / TR Control Panel / LV, TM / MV, TT / HV, (IM-QM, SM6, DM1A), (Floukit): 1. TRAFINDO 2. UNINDO 3. CISCO 4. SCHNEIDER 5. RIK 6. UNEL 7. SIEMENS 8. NGK 9. NIHON 10. NOKIAN 11. LIFASA 12. etc SEAFTY / PROTECTION: 1. YOTSUGI 2. Nomex 3. REGELTEX 4. ELSEC 5. etc GENSET / PART / AVR: 1. CATERPILAR 2. CUMMINS 3. DEUTZ 4. DOOSAN 5. FOTON 6. KOMATSU 7. LOVOL 8. MAN 9. PERKINS 10. MITSUBISHI 11. YANMAR 12. STAMFORD 13. etc Power factor controllers N-6, N-12 and NC-12 NOKIAN